We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Gas removal tower.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Gas removal tower×イーテクノ 本社 - List of Manufacturers, Suppliers, Companies and Products

Gas removal tower Product List

1~3 item / All 3 items

Displayed results

[Environmental Equipment Delivery Case] High-Concentration Chlorine Gas and Cyanide Gas Removal Tower

The outlet concentration should be below 2ppm for cyanide gas! We will introduce examples of the delivery of high-concentration chlorine gas and cyanide gas removal towers.

We would like to introduce a case study of the delivery of a high-concentration chlorine gas and cyanide gas removal tower conducted by E-Techno. The target gases for removal are chlorine gas and cyanide gas, with a maximum treatment gas volume of 3600 Nm³/h. The inlet concentration is a maximum of 2 vol% for chlorine gas and 15 vol% for cyanide gas, while the outlet concentration is 0.5 ppm for chlorine gas and below 2 ppm for cyanide gas. 【Case Study】 ■ Industry of Delivery: Chemical ■ Designed and Installed Equipment: High-Concentration Chlorine Gas and Cyanide Gas Removal Tower ■ Treatment Gas Volume: Max. 3600 Nm³/h ■ Target Gases for Removal: Chlorine Gas, Cyanide Gas ■ Inlet Concentration: Max. 2 vol% for Chlorine Gas, 15 vol% for Cyanide Gas ■ Outlet Concentration: 0.5 ppm for Chlorine Gas, below 2 ppm for Cyanide Gas *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other environmental equipment
  • Gas recovery/treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment] Hydrochloric Acid Gas Removal Tower

The absorption by water is Max 90°C! We will introduce a case where the outlet concentration of hydrochloric acid gas was below 5 ppm.

Here is a case study of the hydrochloric acid gas removal tower delivered by E-Techno to the steel industry. The absorption using water is at a maximum of 90°C. The processing gas volume is 6750 Nm³/h, and the target gases and their concentrations are trace amounts of HCl, trace amounts of Cl2 gas, dust, and Fe2O3. The outlet concentration is less than 5 ppm for hydrochloric acid gas, while chlorine gas and dust are at natural levels. [Case Study] - Industry of delivery: Steel manufacturing - Designed and installed equipment: Hydrochloric acid gas removal tower, E730 series - Processing gas volume: 6750 Nm³/h - Target gases and concentrations: trace amounts of HCl, trace amounts of Cl2 gas, dust, Fe2O3 - Outlet concentrations: - Hydrochloric acid gas: less than 5 ppm - Chlorine gas: natural levels - Dust: natural levels *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other environmental equipment
  • Gas recovery/treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Environmental Equipment Delivery Case】Methyl Acrylate Gas Removal Tower

Removal rate of over 90% of the design value! Case study of removal target gases such as methyl acrylate and toluene.

We would like to introduce a case of the delivery of a methyl acrylate gas removal tower conducted by E-Techno. The target gases and their concentrations are methyl acrylate at 200 ppm, toluene at 1600 ppm, cyclohexane at 100 ppm, and methanol at 20 ppm. The processing gas volume is 6000 m³/h, with a removal rate of over 90% as per design specifications. 【Case Details】 ■ Industry of delivery: Chemical ■ Designed and installed equipment: Methyl acrylate gas removal tower E730 series ■ Processing gas volume: 6000 m³/h ■ Gas temperature: 35℃ ■ Removal rate: Over 90% as per design specifications ■ Packing tower: ID 1200×H5015 (packing height 2m) SUS304 ■ Packing material: Hyrex 200PP *For more details, please refer to the PDF document or feel free to contact us.

  • Gas recovery/treatment equipment
  • others
  • Other environmental equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration